QA items on CFCC® core before Shipping | Applicable Standard |
---|---|
Verification test (visual inspection, diameter, dimension, Unit weight, Laying pitch)
|
ASTM B 987, In-house standard |
Tensile test (Breaking load, Tensile Modulus, Elongation)
|
JIS A 1192, ASTM B 987 (ASTM D 3918), In-house standard |
Glass transition temperature test (Tg at DMA method)
|
ISO 6721-1, ASTM B 987 (ASTM D 7028), In-house standard |
Bending tests and Dye penetrant test / Tensile test after Bending test
|
ASTM B 987, In-house standard |
Torsion test
|
HTLS Guidelines (India CEA), In-house Standard |
Flexural test (3-point bending test)
|
ISO 14125, ASTM D 7264 |
Heat exposure test (400 hours) and tensile test after heat exposure test
|
As required by customer specification |
CTE test (TMA method)
|
ISO 11359-1 and 2, In-house standard |
QA Items on CFCC® core (Type Test) | Applicable Standard |
---|---|
Verification test (visual inspection, diameter, dimension, Unit weight, Laying pitch)
|
ASTM B 987, In-house standard |
Tensile test (Breaking load, Tensile Modulus, Elongation)
|
JIS A 1192, ASTM B 987 (ASTM D 3918), In-house standard |
Glass transition temperature test (Tg at DMA method)
|
ISO 6721-1, ASTM B 987 (ASTM D 7028), In-house standard |
Bending tests and Dye penetrant test / Tensile test after Bending test
|
ASTM B 987, In-house standard |
Torsion test
|
HTLS Guidelines (India CEA), In-house standard |
Flexural test (3-point bending test)
|
ISO 14125, ASTM D 7264 |
Long-term thermal resistance test (based on Arrhenius model)
|
IEC 60216-1 and 3, In-house standard |
CTE test (TMA method)
|
ISO 11359-1 and 2, In house standard |
Heat Exposure Test
|
ASTM B 987, In-house standard |
Heat/Stress Test
|
ASTM B 987 |
Salt Spray Test on aluminum wires (galvanic protection characteristic)
|
ISO 9227, ASTM B 117 |
Tensile Test at operating temperature
|
In-house standard |
Porosity check test (digital microscope)
|
IEC/TS 62818-1 CD |
Vibration fatigue test
|
As required by customer specification |
Brittle fracture test
|
CIGRE TB 426 IEEE Report |
Damp heat test (to check the CFCC deterioration after high-temperature, high humidity)
|
JIS C 60068-2-78 (IEC 60068-2-78) |
Tensile Test / Flexural test (3-point bending) at very low temperature (less than -20°C)
|
As required by customer specification |
QA Items on ACFR® conductor (Type Test) | Applicable Standard |
---|---|
Verification test (visual inspection, diameter, dimension, Unit weight, Laying pitch, etc)
|
IEC 61089, IEC 62219, EN 50540, As required by customer specification |
Stress-Strain test
|
IEC 61089, EN 50540 etc |
Breaking Strength test / Ultimate strength test
|
IEC 61089, EN 50540 etc |
DC Resistance test
|
EN 50540 etc |
Creep test
|
IEC 61395 |
Sheave test
|
IEEE 1138 etc |
Temperature Cycle test
|
As required by customer specification |
QA Items on ACFR® hardware & accessories (Type Test) | Applicable Standard |
---|---|
Visual Inspection, Dimension
|
IEC 61284, ANSI C119.4 / As required |
Compression test
|
JEC 3410 |
Electric Resistivity test
|
JEC 3410 |
Tensile test
|
IEC 61284, ANSI C119.4 / As required by customer specification |
Heat Run test
|
JEC 3410 |
Heat Cycle test
|
IEC 61284, ANSI C119.4 / As required by customer specification |
Freezing seizing power test
|
As required by customer specification |
High temperature tensile test
|
As required by customer specification |
Fatigue test
|
As required by customer specification |
Long term tensile test
|
As required by customer specification |
Sustain Load test
|
ANSI C119.4 |
Aeolian vibration test
|
IEEE 1138 / As required by customer specification |